Chapter 4 Operation
4.2 Operation in Positioner Mode
4.2.2 Operation in Positioner Mode 1
174
䎃
䎃
䎃
䎃
䎃
䎃
䎃
䎃
䎃
䎃
䎃
䎃
䎃
䎃
If there is a problem in this operation, have an interlocking to the start signal by the home-return complete
signal HEND since there is the home-return signal HOME in PIO Pattern 1.
There is no home-return signal in PIO Pattern 2. Therefore, it is necessary to set 0.00mm to one of the
position numbers as a position for positioning, and perform positioning to that position. The actuator
performs positioning to the home position and the home-return complete signal HEND turns ON. Interlock
the setting so positioning cannot be conducted at other positions by the home-return complete signal
HEND.