beautypg.com

IAI America ERC3 User Manual

Page 129

background image

Chapter 3 Wiring

3.3 Positioner Mode 2 (Extension

Type by PIO Converter)

119

3) PIO Pattern 2 ··················256-point mode (Number of positioning points : 256-point type)

0V(NPN Type)

1A

PM1

1B

24V DC(NPN Type)

24V DC(PNP Type)

2A

PM2

2B

0V(PNP Type)

Command Position No.1

3A

PC1

PM4

3B

Completed Position No.1

Command Position No.2

4A

PC2

PM8

4B

Completed Position No.2

Command Position No.4

5A

PC4

PM16

5B

Completed Position No.4

Command Position No.8

6A

PC8

PM32
PM64

PM128

6B

Completed Position No.8

Command Position No.16

7A

PC16

7B

Completed Position No.16

Command Position No.32
Command Position No.64

Command Position No.128

8A

PC32
PC64
PC128

8B

Completed Position No.32
Completed Position No.64
Completed Position No.128

Brake Forcible Release

9A

BKRL

9B

10A

10B

Home Return

11A

HOME

HEND

11B

Pause

12A

*STP

PEND

12B

Start

13A

CSTR

SV

13B

Reset

14A

RES

*EMGS

14B

Servo ON

15A

SON

*ALM

15B

16A

16B

17A

17B

18A

18B

19A

19B

20A

20B

PIO Converter

Position Zone/Zone 1

Home Return Completion
Position Completion
Servo ON Output
Emergency Stop Output
Alarm

BR- 1

RD- 1

OR- 1

YW- 1

GN- 1

BL- 1
PL- 1

GY- 1

WT- 1

BK- 1

BR- 2

RD- 2

OR- 2

YW- 2

GN- 2

BL- 2
PL- 2

GY- 2

WT- 2

BK- 2

BR- 3
RD- 3
OR- 3
YW- 3
GN- 3
BL- 3
PL- 3
GY- 3
WT- 3
BK- 3
BR- 4
RD- 4
OR- 4
YW- 4
GN- 4
BL- 4
PL- 4
GY- 4
WT- 4
BK- 4

PZONE

/ZONE1

*ALML

Light Error Output

“*” in codes above shows the signal of the active low. Processing occurs when an input signal

of the type is turned OFF. An output signal of the type is normally ON in the power-on status

and turned OFF at signal output.

Ɣ Use the attached cable for the I/O connection.

Model : CB-PAC-PIOƑƑƑ (ƑƑƑ indicates the cable length L. Example. 020 2m)

Flat Cable (20-core) × 2

BK-4 (20B)

BR-3 (1B)
BK-2 (20A)

BR-1 (1A)

20A

20B

1A

1B

Half Pitch MIL Socket

HIF6-40D-1.27R (Hirose Electric)

A

B

L

No treatment

conducted

No treatment

conducted