2] load attachment – IAI America ERC3 User Manual
Page 87
Chapter 2 Installation
2.3 How to Install
77
[2] Load Attachment
• There is a restriction on the moment and load overhang length when attaching a load to the
slider.
Allowable load moment and overhang load length
Allowable Static Load
Moment [N•m]
Allowable Dynamic Load
Moment
(Note 1)
[N•m]
Actuator
Type
Ma
Mb
Mc
Ma
Mb
Mc
Allowable Overhung Load
Length L [mm]
SA5C
29.4
42
60.5
7.1
10.2
14.7
Ma direction: 150
Mb or Mc direction: 150
SA7C
70
100
159.5
15
21.4
34.1
Ma direction: 150
Mb or Mc direction: 150
Note 1 Provided under assumption that the operation life is 5,000km.
Mb direction
Direction of allowable overhang
Direction of moment
Ma direction
L
Mb or Mc direction
L
Mc direction
Ma direction
Load
Load
Load
Load
For the calculation of Ma and Mc moments, consider the position indicated with an arrow as the
datum point.
Caution: An operation beyond the allowable moment and overhang load length would not only
generate abnormal noise and vibration, but also may shorten the life of actuator
extremely.
ERC3-SA5C
ERC3-SA7C