Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.2 Operation in Positioner Mode 1

186

Caution: (1) If the ST* signal is turned ON for the position after completion of

positioning, both the PE* signal remain ON (except the pitch feed

operation).

(2) PE* Signal turns ON when the actuator gets into the positioning

width. Accordingly, they may be turned ON under operation of the

actuator if a large positioning width is set.

(3) Interlock should be taken so that two or more ST* signals are set to

ON simultaneously.

1) Entering the ST* signal of another position during positioning is

invalid. If the ST* signal of another position is turned ON during

positioning, the operation is terminated after the completion of

the positioning being operated.

2) Entering the ST* signal of another position with the ST* signal of

the current position remaining ON after the completion of

positioning allows the positioning to the other position to be

executed.

(4) If Parameter No.27 “Move command type” is set to “0” (factory

setting), turning ST* OFF during positioning caused the operation to

be interrupted.

[Important] Home return

In the first positioning operation after the power is supplied, home-return operation is automatically

performed, and then positioning operation with the data of the indicated position number starts.

There is no home-return command in Pattern 1. Have a home return in this way.










If there is a problem in this operation, set 0.00mm to one of the position numbers as a position for

positioning, and perform positioning to that position. The actuator performs positioning to the home

position and PE* of the indicated position turns ON. Interlock the setting so positioning cannot be

conducted at other positions by this PE* Signal.

Start signal

ST*

(PLCoController)䎃

Positioning completion signal

PE*

(ControlleroPLC)䎃

Target Position

Home Return

Completion

T1•6ms

Turned OFF by

turning PE* OFF

Turned ON

after entering

into positioning

width zone

Positioning

Home return

Start signal

ST*

(PLCoController)

Turned ON after

entering into

positioning width

zone

Target

Position

Current position No.

PE*

(ControlleroPLC)

Turned OFF by

turning PE* ON