2] overview of major functions – IAI America ERC3 User Manual
Page 208
Chapter 4 Operation
4.2 Operation in Positioner Mode
4.2.3 Operation in Positioner Mode 2 (Operation Using PIO Converter)
198
[2] Overview of major Functions
Major functions
Description
Number of positioning points
Number of positioning points which can be set in the
position table.
Operation with the Position No.
Input
Normal operation started by turning the start signal ON after
position No. is entered with binary data.
Position No. direct command
operation
Operation enabled by turning the signal directly
corresponding to a position No. ON
Positioning
Positioning enabled at an arbitrary position by the data set in
the position table
Velocity change during the
movement
Velocity change enabled by activating another position No.
during movement
Pressing (tension)
Operation by an arbitrary pressing (tension) force set in the
position table enabled
Pitch feeding
(relative moving feed)
Pitch feed by an arbitrary moving distance set in the position
table enabled
Home return signal input
Input signal exclusively used for home return. Set to ON to
start home return
Pause
The operation can be interrupted or continued by setting this
signal to ON or OFF, respectively.
Jog moving signal
The actuator can only be moved while the input is set to ON.
Teaching signal input
(Current position writing)
Setting the input signal to ON allows the coordinate value in
the stop state to be written to the position table.
Brake release signal input
The brake (option) can only be released while the input is
set to ON.
Moving signal output
The output signal is set to ON while the actuator is moved.
Zone signal output
The output signal is set to ON while the actuator is entered
within the zone defined by the coordinate values set as
parameters.
Position zone signal output
The output signal is set to ON while the actuator is entered
within the zone defined by the coordinate values set in the
position table.