Chapter 6
Adjustment of Operation
6.2 High Output Setting and Gain Scheduling Function
302
6.2.4 Setting in MEC Mode 1 to 3
Making the high output setting enable/disable is to be conducted in Parameter No.28.
The high output setting is set enable at the delivery.
With the setting of enable/disable for the high output setting, the parameters are switched over
between “Velocity Loop Proportional Gain” and “Velocity Loop Integrated Gain” to perform
controls.
Shown in the table below is the parameter numbers of “Velocity Loop Proportional Gain” and
“Velocity Loop Integrated Gain” to be enable by the setting conditions.
0 (Disable)
Parameter No.5, 6
High output setting
(Parameter No.152) 1 (Enable = in Delivery)
Parameter No.29, 30
Caution: Please note that the high output setting automatically turns disable if
Quick Teach equipped with a power supply unit (PCM-PST-1,
PCM-PST-2 or PCM-PST-EU) is connected.
- ERC2 (138 pages)
- ERC2 (188 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- NS (78 pages)
- ICS(P)A (16 pages)
- RS (46 pages)