IAI America ERC3 User Manual
Page 355
Chapter 6
Adjustment of Operation
6.3 I/O Parameter
6.3.2 MEC Mode 1, MEC Mode 2 and MEC Mode 3
345
(15) Home return direction (Parameter No.17)
No.
Name
Symbol
Unit
Input Range
Default factory setting
17 Home return direction
ORG
–
0: Reverse
1: Forward
In accordance with
actuator
Unless there is an indication of home-reversed type (option), the direction of the home return
for the straight axis is located on the motor side. [Refer to the coordinate system of the
actuator.]
If it becomes necessary to reverse the home direction after the actuator is installed on the
machine, change the setting.
Caution: The home direction cannot be changed for the rod type actuators.
(16) Simple absolute unit (Parameter No.18)
No.
Name
Symbol
Unit
Input Range
Default factory setting
18 Simple absolute unit
ETYP
–
0 : Enabled
1 : Disabled
0
Set to 1 for Simple Absolute Type of PIO Converter, and 0 for others.
(17) Absolute battery retention time (Parameter No.19)
No.
Name
Symbol
Unit
Input Range
Default factory setting
19
Absolute battery retention
time
AIP
days
0: 20 days
1: 15 days
2: 10 days
3: 5 days
0
For Simple Absolute Type, establish the setting to define how long the position information of
the encoder is to be remained for after the power to the controller is turned OFF. Setting can be
done from four grades. Maximum number of the motor revolution due to external force during
the power is OFF is controlled by the set days. Establish the setting assuming the speed when
the work transporting parts, slider or rod, on the actuator is moved by external force during the
power being OFF. The position information will lose if the number of motor revolution exceeds
the set value. Consider safety margin when establishing the setting.
Motor
rotation
[rpm]
Moved speed [mm/s] / Lead length [mm]
u
60
Setting
Position information
retaining day (reference)
Motor max. rotation speed
(rpm)
0 (Initial setting)
20 days
100
1
15 days
200
2
10 days
400
3
5 days
800