Item
Description
Power-supply Voltage
24V DC r10%
High output setting is enabled (Set in delivery) : 3.5A (MAX. 4.2A)
Load Current
(including current consumption for control) High output setting is disabled : 2.2A
Power Supply for Electromagnetic Brake
(Note 1)
(In the case of the actuator with a brake)
24V DC ±10% 0.15A (MAX.)
High output setting is enabled (Set in delivery) : 8.0W
Heat Generation
High output setting is disabled : 5.0W
Rush Current
(Note 2)
8.3A
Transient Power Cutoff Durability
MAX. 500Ps
Motor Control System
Weak field-magnet vector control
Applicable Encoder
Incremental Encoder Resolution 800pulse/rev
Actuator Cable Length
MAX. 10m
Serial Communication Interface
(SIO Port)
RS485 : 1CH (based on Modbus Protocol RTU/ASCII)
Speed : 9.6 to 230.4Kbps
Control available with serial communication in the modes other than the pulse train
PIO Type
Signal I/O dedicated for 24V DC (selected from NPN/PNP) ̖ Input 6 points max.,
output 4 points max.
Cable length MAX. 10m
External Interface
Fieldbus Type
Not applicable
Data Setting and Input
PC Software, Teaching Pendant
Data Retention Memory
Position data and parameters are saved in the nonvolatile memory.
(There is no limitation in number of writing)
SE/NP/PN
Positioner Mode
Operation Mode
(I/O Type)
PLN/PNP
Pulse Train Control Mode
Number of Positions in Positioner
Mode
Standard 8 points, MAX. 16 points
(Note) Number of positions differs depending on the selection in PIO pattern.
Differential System (Line Driver System) : MAX.200kpps
Cable length MAX. 10m
Input Pulse
Open Collector System : Not applicable
(Note 3)
Command Pulse
Magnifications
(Electronic Gear: A/B)
1/50 < A/B < 50/1
Setting Range of A and B (set to parameter) : 1 to 4096
Pulse
Train
Interface
Feedback Pulse Output
None
LED Display (Mounted on motor unit) 2 colors LED: Servo ON (GN) / Servo OFF (OFF) / Emergency Stop (RD) /
Alarm generated (RD) / Automatic servo-off (Flashing in green)
Electromagnetic Brake Compulsory
Release Switch
Not equipped on main unit, equipped on PIO Converter (option)
Insulation Resistance
500V DC 10M: or more
Protection Function against Electric Shock Class I basic insulation
Cooling Method
Natural air-cooling
Surrounding Air Temperature
0 to 40qC
Surrounding Humidity
85%RH or less (non-condensing)
Surrounding Environment
[Refer to Installation Environment]
Surrounding Storage Temperature 0 to 60qC (0 to 50qC if stored for 1 month or more.)
Surrounding Storage Humidity
85%RH or less (non-condensing)
Usage Altitude
1000m or lower above sea level
Protection Class
IP20
Vibration Durability
Frequency 10 to 57Hz / Swing width : 0.075mm
Frequency 57 to 150Hz / Acceleration : 9.8m/s
2
XYZ Each direction Sweep time: 10 min. Number of sweep: 10 times
E
nv
iro
nm
en
t
(N
ot
e
4)
Impact
150mm/s
2
, 11mm/s Semi-sine wave pulse to each of the directions X, Y and Z
Weight
External Dimensions
Refer to specifications for actuator for it is integrated with controller
Note 1 It is the power source to be supplied when compulsorily releasing the brake.
Note 2 Rush current passes for about 5ms after the power is injected (at 40qC).
The rush current value varies depending on the impedance of the power line.
Note 3 If the pulse train applies the open collector output, prepare AK-04 (option) separately to convert to the
differential type.
Note 4 The environmental specifications include the actuator main unit.