Chapter 3 Wiring
3.5 MEC Mode 2 (Operation Using PIO Converter)
132
[2] Operation Patterns and Signal Assignments
The signal assignment of cable by the operation pattern is as shown below. Follow the
following table to connect the external equipment (such as PLC).
Operation pattern
Stopping at 2 points
(2-point positioning)
Stopping at 3 points
(3-point positioning)
Pin
No.
Wire
Color
Category
Movement by 1 input
between 2 points
[Single-solenoid mode]
Movement by 2 input
between 2 points
[Double-solenoid mode]
Movement by 2 input
between 3 points
[3-point positioning]
1A
BR-1
–
–
2A
RD-1
–
–
3A
OR-1
–
–
4A
YW-1
–
–
5A
GN-1
IN0
ST0
ST0
6A
BL-1
IN1
–
ST1
7A
PL-1
IN2
RES
RES
8A
GY-1
IN3
–
–
9A
WT-1
IN4
–
–
10A
BK-1
IN5
–
–
11A
BR-2
IN6
–
–
12A
RD-2
IN7
–
–
13A
OR-2
IN8
–
–
14A
YW-2
IN9
–
–
15A
GN-2
IN10
–
–
16A
BL-2
IN11
–
–
17A
PL-2
IN12
–
–
18A
GY-2
IN13
–
–
19A
WT-2
IN14
–
–
20A
BK-2
Input
IN15
–
–
1B
BR-3
OUT0
LS0/PE0
LS0/PE0
2B
RD-3
OUT1
LS1/PE1
LS1/PE1
3B
OR-3
OUT2
HEND
LS2/PE2
4B
YW-3
OUT3
*ALM
*ALM
5B
GN-3
OUT4
–
6B
BL-3
OUT5
–
7B
PL-3
OUT6
–
8B
GY-3
OUT7
–
9B
WT-3
OUT8
–
10B
BK-3
OUT9
–
11B
BR-4
OUT10
–
12B
RD-4
OUT11
–
13B
OR-4
OUT12
–
14B
YW-4
OUT13
–
15B
GN-4
OUT14
–
16B
BL-4
Output
OUT15
–
17B
PL-4
–
18B
GY-4
–
19B
WT-4
–
20B
BK-4
–
Signal with “*” expresses the signal of active low.
(Reference) Signal of Active Low
Signal with “*” expresses the signal of active low. A signal of active low is a signal that the input signal is
processed when it is turned OFF, output signal is ordinary ON while the power is ON, and turns OFF when
the signal is output.