beautypg.com

7 wiring method, 1 wiring of actuator, Chapter 3 wiring 3.7 wiring method – IAI America ERC3 User Manual

Page 152: Erc3 r = 45mm or more

background image

Chapter 3 Wiring

3.7 Wiring Method

142

3.7 Wiring Method

3.7.1 Wiring of Actuator

Use a dedicated connection cable of IAI for connection.

[1] PIO type power and I/O cable (Model : CB-ERC3P-PWBIOƑƑƑ)

ƑƑƑ indicates the cable length L. (Example 030 = 3m), MAX. 10m

L

V0.5-3 (J.S.T. Mfg.)

V0.5-3 (J.S.T. Mfg.)

CN1

150

Model code display

BA

25

20

9

9

33

Resectable Housing: 1-1827863-3 (AMP)×1

Contact: 1827570-3 (AMP)×23

FG

AWG22

N.C

BK

AWG28

EMG

N.C

N.C

CP

AWG22

CP_GND

MP

AWG19

MP_GND

SA

AWG28

SB

/PP

PP

/NP

NP

IN0

IN1

IN2

IN3

IN4

IN5

OUT0

OUT1

OUT2

OUT3

Signal

Name

Pin

No.

Cable

Color

Drain

RD 1

OR 1

BR

RD

OR

YW

GN

BR 1

BL

PU

GY

WT

BR 2

RD 2

OR 2

YW 2

GN 2

BL 2

PU 2

GY 2

WT 2

BK

A1

A2

A3

A4

A5

A6

B1

B2

B3

B4

B5

B6

A7

B7

A8

B8

A9

B9

A10

B10

A11

B11

A12

B12

A13

B13

Cable

Size

Ɣ Cable bending radius

It is a robot cable, which can be used for moving parts.

PLC (Host System)

ERC3

r = 45mm or more