Chapter 3 Wiring
3.2 Pulse
Train Control Mode
102
3.2.2 PIO Pattern Selection and PIO Signal
[1] PIO Pattern (Control Pattern) Selection
There are two types of control method for the pulse train control. Set an appropriate PIO
pattern suited to the use to Parameter No.25 “PIO Pattern Select”.
Refer to 4.3 Operation in Pulse Train Control Mode for the details of PIO patterns.
Type
Value set in
parameter
No.25
Mode
Overview
PIO
Pattern 0
0
(at the
delivery)
Positioning mode • Positioning with Pulse Train
PIO
Pattern 1
1
Pressing mode
• Positioning with Pulse Train
• Pressing operation with torque control
available
[2] PIO pattern and Signal Allocation
The signal assignment of cable by the PIO pattern is as shown below. Follow the following
table to connect the external equipment (such as PLC).
Parameter No.25 (PIO Pattern) Selection
0
1
Pin No. Wire Color
Category
PIO Function
Positioning mode
Pressing mode
A1
Drain
Frame ground
FG
B1
BR
Control power unit +24V
CP
A2
–
–
–
B2
RD
Control power unit 0V
CP_GND
A3
RD 1
Brake release
BK
B3
OR
Motor power unit +24V
MP
A4
OR 1
Emergency-stop input
EMG
B4
YW
Motor power unit 0V
MP_GND
A5
–
–
–
B5
GN
–
–
A6
–
–
–
B6
BR 1
–
–
A7
BL
–
/PP
B7
PL
–
PP
A8
GY
–
/NP
B8
WT
–
NP
A9
BR 2
IN0
SON
SON
B9
RD 2
IN1
TL
TL
A10
OR 2
IN2
HOME
HOME
B10
YW 2
IN3
RES
RES/DCLR
A11
GN 2
IN4
–
–
B11
BL 2
Input
IN5
–
–
A12
PL 2
OUT0
SV
SV
B12
GY 2
OUT1
INP
INP/TLR
A13
WT 2
OUT2
HEND
HEND
B13
BK
Output
OUT3
*ALM
*ALM
Signal with “*” expresses the signal of active low.
(Reference) Signal of Active Low
Signal with “*” expresses the signal of active low. A signal of active low is a signal that the input signal is
processed when it is turned OFF, output signal is ordinary ON while the power is ON, and turns OFF when
the signal is output.