Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

332

(67) Total operated distance threshold (Parameter No.148)

No.

Name

Symbol

Unit

Input Range

Default factory setting

148 Total operated distance

threshold

ODOT

m

0 to 999999999

0 (Disabled)

Notice will be made with Movement Distance Threshold Exceeding Alarm (04F) if the total

distance of movement exceeds the value set in this parameter.

The judgment would not be made if the value is set to 0.

(68) Zone output changeover (Parameter No.149)

No.

Name

Symbol

Unit

Input Range

Default factory setting

149 Zone output changeover

FPIO

0: Not to change

1: To change

0

The enable zone signals are determined by the setting of this parameter and the setting of

Parameter No.25 “PIO Pattern Select”.

The relationship between the parameter settings and enable zone signal outputs are as shown

in the table below.

Parameter No.149 Zone Output Changeover

Operating Mode

Parameter No.25

PIO Pattern Selection

0

1

0

ZONE1 no matter settings

1

There are no zone outputs

Positioner Mode 1

2

PZONE

ZONE1

0

ZONE1

PZONE

ZONE1

ZONE2

1

2

PZONE

ZONE1

3

There is no zone signal output

4

Positioner Mode 2

5

ZONE1

PZONE

ZONE1

ZONE2

Pulse Train Mode

There is no zone signal output

(69) High output setting (Parameter No.152)

No.

Name

Symbol

Unit

Input Range

Default factory setting

152 High output setting

BUEN

0: Disable

1: Enable

1 (Enabled)

Establish the setting of enable/disable for the high output function.