424
Configure a secondary call on a call node (match a number)
Network requirements
As shown in
, configure an IVR access number and call node functions on Router B to meet the
following requirements.
•
After the subscriber dials 300 (the IVR access number) from Telephone A, Router B plays the audio
file welcome.wav. Configure number match so that when the subscriber dials 50, Telephone B1
rings.
•
If the subscriber dials a wrong number at Telephone A, Router B plays the audio file
input_error.wav.
•
If no number is dialed at Telephone A within the timeout time, Router B plays the audio file
timeout.wav.
Figure 813 Network diagram
Configuration procedure
1.
Configure Router A: See
.
2.
Configure Router B:
# Configure a call node.
Select Voice Management > IVR Services > Advanced Settings from the navigation tree, select the
Configure Call Node tab, and click Add to access the following page.
Telephone A
50
Eth1/1
1.1.1.1/24
Router A
Router B
100
Eth1/1
1.1.1.2/24
Telephone B2
Telephone B1
500