Item Description

Signal Type

Specify the signal type. Types 1, 2, 3, and 5 are the four signal
types (that is, types I, II, III, and V) of the analog E&M subscriber line.
When you configure the signal type, make sure the signal type is the
same as that of the peer device.
The configuration will be applied to all analog E&M lines in the
corresponding slot.

Max Interval for Dialing the Next Digit

Specify the maximum interval for the user to dial the next digit.
This timer will restart each time the user dials a digit and will work in
this way until all the digits of the number are dialed. If the timer

expires before the dialing is completed, the user will be prompted to

hook up and the call is terminated.

Max Duration the System Waits for the
First Digit

Specify the maximum duration for the system to wait for the first digit
of a number.

Max Duration of Playing Ringback
Tones

Specify the maximum duration in seconds of playing ringback tones.

Status

Enable.

Disable.

Advanced Settings

Start
Mode

Immediate
Start

Delay Time
before the Calling
Party Sends

DTMF Signals in

Immediate Start
Mode

Specify the delay time before the calling party sends DTMF signals
in the immediate start mode.

Delay
Start

Delay Signal
Duration in Delay

Start Mode

Specify the delay signal duration in the delay start mode.

Delay Time
before the Called

Party Sends a
Delay Signal in

Delay Start Mode

Specify the delay time from when the called party detects a seizure
signal to when it sends a delay signal in the delay start mode.

Wink
Start

Delay Time
before the Called

Party Sends a
Wink Signal in

Wink Start Mode

Specify the delay time from when the called party receives a seizure
signal to when it sends a wink signal in the wink start mode.

Duration of a
Wink Signal

Send by the

Called Party in
Wink Start Mode

Specify the time duration the called party sends wink signals in the
wink start mode.

Max Time the
Calling Party

Waits for a Wink

Signal in Wink
Start Mode

Specify the maximum amount of time the calling party waits for a
wink signal after sending a seizure signal in the wink start mode.