21.

Add a rule as shown in

Figure 785

.

22.

Click Apply.

# Apply call rule set 2.

23.

Select Voice Management > SIP Local Survival > Call Authority Control from the navigation tree,
and click the icon of call rule set 2 to access the following page.

Figure 786 Applying call rule set 2

24.

Click 5000 in Available register users, and then click << to add it to Register users bound to the
rule set.

25.

Click Apply.

Configuring Router A

1.

Configure a local number in the local number configuration page: The ID is 1000, the number is

1000, the bound line is line2/0, the user name is 1000, and the password is 1000.

2.

Configure a local number in the local number configuration page: The ID is 1111, the number is
1111, the bound line is line2/1, the user name is 1111, and the password is 1111.

3.

Configure a call route to Router B in the call route configuration page: The ID is 5000, the
destination number is 5…, the routing type is SIP, and the SIP routing method is proxy server.

4.

Configure SIP registration in the connection properties configuration page: Enable SIP registration,
and configure the main registrar’s IP address as 2.1.1.2.

Configuring Router B

1.

Configure a local number in the local number configuration page: The ID is 5000, the number is

5000, the bound line is line2/0, the user name is 5000, and the password is 5000.