beautypg.com

Configuration considerations, Configuration procedure – H3C Technologies H3C MSR 50 User Manual

Page 760

background image

375

Figure 755 Network diagram

Configuration considerations

Configure one-to-one binding between FXS and FXO voice subscriber lines.

When the IP network is available, the VoIP entity is preferably used to make calls over the IP
network.

When the IP network is unavailable, the POTS entity is used to make calls through the bound FXO
voice subscriber line over the PSTN.

Configuration procedure

Router A and Router B are routable to each other.
The configuration of interface IP addresses is not shown.

1.

Configure Router A:
# Configure a local number and two call routes.

a.

Configure a call route in the call route configuration page: The call route ID is 210, the
destination number is 210…., and the destination address is 192.168.0.76.

b.

Configure a local number in the local number configuration page: The number ID is 0101001,
the number is 0101001, and the bound line is 3/0.

c.

Configure the backup call route 211 for the FXO line in the call route configuration page: The

destination address is .T, call route type is Trunk, and the trunk route line is 4/0. In addition,
select the Send All Digits of a Called Number option in the Called Number Sending Mode area

when you configure the advanced settings of this call route.

# Configure call authority control.

d.

Select Voice Management > Dial Plan > Call Authority Control from the navigation tree, and
then click Add to access the permitted call number group configuration page.

This manual is related to the following products: