Configuring the snmp agent, Configuring the snmp nms – H3C Technologies H3C MSR 50 User Manual

Page 534

background image

149

Figure 539 Network diagram

Configuring the SNMP agent

1.

Select System Management > SNMP from the navigation tree, and then perform configuration as

shown in

Figure 540

.

Figure 540 Configuring the SNMP agent

2.

Select the Enable option.

3.

Select the SNMPv1 & v2 option.

4.

Type readonly in the field of Read Password.

5.

Type read&write in the field of Read & Write Password.

6.

Type read&write in the field of Trap Password.

7.

Type 1.1.1.2 in the field of Trap Target Host Address/Domain.

8.

Click Apply.

Configuring the SNMP NMS

The configuration on the NMS must be consistent with that on the agent. Otherwise, you cannot perform

corresponding operations.

1.

Configure the SNMP version for the NMS as v1 or v2c.

2.

Create a read-only community public and set the read-only password to readonly.

3.

Create a read and write community and set the read and write password to readwrite.

For more information about configuring the NMS, see the NMS manual.