beautypg.com

HP Array Controller HSG V8.7 Software User Manual

Page 77

background image

Configuring an HSG80 Array Controller

2–23

Table 2–6 Key to Figure 2–9 Cabling for Dual-Redundant

Configuration with One Hub using Fibre Channel
Optical Support

1. Stop all I/O from the host to its devices on the bus to which you are

connecting the controllers.

2. For this configuration, set Port 2 off-line using the SET

THIS_CONTROLLER PORT_2_TOPOLOGY=OFFLINE command.
See Appendix B, “CLI Commands,” for details about the SET
command.

3. Connect the Fibre Channel cable from Port 1 on controller A to Port 9

on hub 1. Repeat this step to connect the second cable from Port 1 on
controller B to Port 8 on hub 1.

4. Connect another Fibre Channel cable from Port 2 on controller A to Port

1 on hub 2. Repeat this step to connect the final cable from Port 2 on
controller B to Port 2 on hub 2.

5. Connect each hub to their respective host according to the instructions

supplied in the Getting Started manual.

6. Route and tie the cables as desired.

7. Restart the I/O from the host. Some operating systems may require you

to restart the host to see the devices attached to the new controller.

Item Description

Part

No.

1

Dual Controller

2

12-Port Fibre Channel HUB

DHGGA-CA

3

.5 M Fibre Channel Optic cable

1 M Fibre Channel Optic cable
2 M Fibre Channel Optic cable
3 M Fibre Channel Optic cable
5 M Fibre Channel Optic cable

10 M Fibre Channel Optic cable
20 M Fibre Channel Optic cable
30 M Fibre Channel Optic cable
50 M Fibre Channel Optic cable

100 M Fibre Channel Optic cable
200 M Fibre Channel Optic cable
400 M Fibre Channel Optic cable

17–04820–01
17–04820–02
17–04820–03
17–04820–04
17–04820–05
17–04820–06
17–04820–07
17–04820–08
17–04820–09
17–04820–10
17–04820–11
17–04820–12