Event Reporting: Templates and Codes

D–33

03FA0D01

The EMU has detected an elevated temperature condition. Note that in
this instance the Associated Target, Associated Additional Sense Code,
and Associated Additional Sense Code Qualifier fields are undefined.

41

03FB0E01

The EMU has detected an external air sense fault. Note that in this
instance the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.

41

03FC0F01

The EMU-detected power supply fault is now fixed. Note that in this
instance the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.

41

03FD0F01

The EMU-detected bad-fan fault is now fixed. Note that in this instance
the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.

41

03FE0F01

The EMU-detected elevated temperature fault is now fixed. Note that in
this instance the Associated Target, Associated Additional Sense Code,
and Associated Additional Sense Code Qualifier fields are undefined.

41

03FF0F01

The EMU-detected external air sense fault is now fixed. Note that in this
instance the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.

41

07030B0A

Failover Control detected a receive packet sequence number mismatch.
The controllers are out of synchronization with each other and are
unable to communicate. Note that in this instance the Last Failure Code
and Last Failure Parameters fields are undefined.

05

07040B0A

Failover Control detected a transmit packet sequence number mismatch.
The controllers are out of synchronization with each other and are
unable to communicate. Note that in this instance the Last Failure Code
and Last Failure Parameters fields are undefined.

05

07050064

Failover Control received a Last Gasp message from the other controller.
The other controller is expected to restart itself within a given time
period. If it does not, it will be held reset with the “Kill” line.

05

07060C01

Failover Control detected that both controllers are acting as SCSI ID 6.
Since ids are determined by hardware, it is unknown which controller is
the real SCSI ID 6. Note that in this instance the Last Failure Code and
Last Failure Parameters fields are undefined.

05

07070C01

Failover Control detected that both controllers are acting as SCSI ID 7.
Since ids are determined by hardware, it is unknown which controller is
the real SCSI ID 7. Note that in this instance the Last Failure Code and
Last Failure Parameters fields are undefined.

05