CLI Commands

B–13

Examples

To add DISK10000 at port 1, target 0, LUN 0, type:

ADD DISK DISK10000 1 0 0

To add DISK40200 as a transportable disk drive to port 4, target 2,
LUN 0, use:

ADD DISK DISK40200 4 2 0 TRANSPORTABLE

To add a disk drive named DISK30200 as non-transportable disk to port
3, target 2, LUN 0, and to set the data transfer rate to 10 MHz, enter the
following command on one line.

ADD DISK DISK30200 3 2 0 NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED=10MHZ

This example creates a host-addressable unit after the disk is added:

INITIALIZE DISK20000

ADD UNIT D199 DISK20000

See also

ADD MIRRORSET
ADD UNIT
DELETE container-name
LOCATE
SHOW DISKS
SHOW DEVICES