HP Array Controller HSG V8.7 Software User Manual

Page 514

background image

D–80

HSG80 User’s Guide

40

If the Sense Data FRU field is non-zero, follow repair action 41. Otherwise, replace the
appropriate FRU associated with the device’s SCSI interface or the entire device.

41

Consult the device’s maintenance manual for guidance on replacing the indicated device
FRU.

43

Update the configuration data to correct the problem.

44

Replace the SCSI cable for the failing SCSI bus. If the problem persists, replace the
controller backplane, drive backplane, or controller module.

45

Interpreting the device supplied Sense Data is beyond the scope of the controller’s
firmware. See the device’s service manual to determine the appropriate repair action, if
any.

50

The RAIDset is inoperative for one or more of the following reasons:

n

More than one member malfunctioned. Perform repair action 55.

n

More than one member is missing. Perform repair action 58.

n

Before reconstruction of a previously replaced member completes another member
becomes missing or malfunctions. Perform repair action 59.

n

The members have been moved around and the consistency checks show mismatched
members. Perform repair action 58.

51

The mirrorset is inoperative for one or more of the following reasons:

n

The last NORMAL member has malfunctioned. Perform repair actions 55 and 59.

n

The last NORMAL member is missing. Perform repair action 58.

n

The members have been moved around and the consistency checks show mismatched
members. Perform repair action 58.

52

The indicated Storageset member was removed for one of the following reasons:

n

The member malfunctioned. Perform repair action 56.

n

By operator command. Perform repair action 57.

53

The STORAGESET may be in a state that prevents the adding of a replacement member,
check the state of the STORAGESET and its associated UNIT and resolve the problems
found before adding the replacement member.

54

The device may be in a state that prevents adding it as a replacement member or may not
be large enough for the STORAGESET. Use another device for the ADD action and
perform repair action 57 for the device that failed to be added.

55

Perform the repair actions indicated in any and all event reports found for the devices that
are members of the STORAGESET.

Table D–4

Recommended Repair Action Codes (Continued)

Code

Description