Figure 6–1 location of write-protection switch, Location of write-protection switch –4 – HP Array Controller HSG V8.7 Software User Manual
Page 250

6–4
HSG80 User’s Guide
Figure 6–1 Location of Write-Protection Switch
6. Start CLCP with the following command:
RUN CLCP
CLCP displays the following:
Select an option from the following list:
Code Load & Patch local program Main Menu
0: Exit
1: Enter Code LOAD local program
2: Enter Code PATCH local program
3: Enter EMU Code LOAD Utility
Enter option number (0..3) [0] ?
7. Enter option 1, Enter Code LOAD local program, from the CLCP Main
menu to start the Code LOAD local program. CLCP displays the
following:
You have selected the Code Load Utility. This utility is used
to load a new software image into the program card currently
inserted in the controller.
Type ^Y or ^C (then RETURN) at any time to abort code load.
The code image may be loaded using SCSI Write Buffer commands
through the SCSI Host Port, or using KERMIT through the
maintenance terminal port.
0: Exit
1: Use the SCSI Host Port
2: Use the Maintenance Terminal Port
Enter option number (0..2) [0] ?
Note You can use either the SCSI host port (if your operating sysem
supports it) or the maintenance port. To use the SCSI host port, go to
step 8. To use the maintenance port, go to step 10.