beautypg.com

Passthrough device reset event sense data response – HP Array Controller HSG V8.7 Software User Manual

Page 436

background image

D–2

HSG80 User’s Guide

Passthrough Device Reset Event Sense Data Response

Events reported by passthrough devices during host/device operations
are conveyed directly to the host system without intervention or
interpretation by the HSG80controller, with the exception of device
sense data that is truncated to 160 bytes when it exceeds 160 bytes.

Events related to pass-through device recognition, initialization, and
SCSI bus communication events that result in a reset of a pass-through
device by the HSG80 controller are reported using standard SCSI Sense
Data, as shown in Figure D–1. For all other events, refer to the
templates to follow.

n

Instance Codes (byte offset 32-35) are described in Table D–1,
“Instance Codes” on page D–18.

n

ASC and ASCQ codes (byte offsets 12 and 13) are described in
Table D–7, “ASC and ASCQ Codes” on page D–85.

Figure D–1

Pass-through Device Reset Event Sense Data
Response Format

off

bit

7

6

5

4

3

2

1

Valid

Segment

FM

Information

Instance Code

Field Replaceable Unit Code

Error Code

0

1

2

3-6

7

8-11

12

13

14

15

16

17

0

Sense Key

Additional Sense Length

Additional Sense Code (ASC)

Additional Sense Code Qualifier (ASCQ)

Sense Key Specific

CXO-5093A-MC

EOM

ILI

Rsvd

SKSV