beautypg.com

HP Array Controller HSG V8.7 Software User Manual

Page 59

background image

Configuring an HSG80 Array Controller

2–5

If you’re configuring dual-redundant controllers, also change the CLI
prompt on the “other controller.” Use the following syntax:

SET OTHER_CONTROLLER PROMPT =

“new prompt”

See Appendix B, “CLI Commands,” for more information about using
the SET OTHER_CONTROLLER PROMPT= command.

12. Optional: Indicate that your subsystem power is supported by a UPS.

Use the following syntax:

SET THIS_CONTROLLER CACHE_UPS

The “other controller” inherits “this controller’s” cache UPS setting.
See “Backing up Power with a UPS,” page 2–13, for more information.

13. Restart the controller, using the following syntax:

RESTART THIS_CONTROLLER

If this is a dual-redundant configuration, restart the “other controller”
using the following syntax:

RESTART OTHER_CONTROLLER

See the RESTART THIS_CONTROLLER command in Appendix B,
“CLI Commands,”
for more information about using this command.

14. When the CLI prompt reappears, it will display details about the

controller you configured. Use the following syntax:

SHOW THIS_CONTROLLER FULL

See the SHOW THIS_CONTROLLER FULL command in Appendix
B, “CLI Commands,”
for more information about using this command.

15. Connect the controller to the host.

See “Connecting the Subsystem to the Host,” page 2–14 for
information about how to complete the connection.

16. Plan and configure storagesets for your subsystem.

See Chapter 3, “Creating Storagesets,” for detailed information about
planning and configuring storagesets.

Note If you have problems during the configuration, use the SET
NOFAILOVER and CONFIGURATION RESTORE commands to reset
the system to the factory settings. You must reset the controller after
these commands are entered to employ the original settings.