Event Reporting: Templates and Codes

D–81

56

Perform the repair actions indicated in any and all event reports found for the member
device that was removed from the STORAGESET. Then perform repair action 57.

57

Delete the device from the FAILEDSET and redeploy, perhaps by adding it to the
SPARESET so it will be available to be used to replace another failing device.

58

Install the physical devices that are members of the STORAGESET in the proper Port,
Target, and LUN locations.

59

Delete the STORAGESET, recreate it with the appropriate ADD, INITIALIZE, and ADD
UNIT commands and reload its contents from backup storage.

5A

Restore the MIRRORSET data from backup storage.

5B

The mirrorset is inoperative due to a disaster tolerance failsafe locked condition, as a
result of the loss of all local or remote NORMAL/NORMALIZING members while
ERROR_MODE=FAILSAFE was enabled. To clear the failsafe locked condition, enter
the CLI command SET unit-number ERROR_MODE=NORMAL.

5C

The mirrorset has at least one local NORMAL/NORMALIZING member and one remote
NORMAL/NORMALIZING member. Failsafe error mode can now be enabled by
entering the CLI command SET unit-number ERROR_MODE=FAILSAFE.

80

An EMU fault has occurred.

81

The EMU reported terminator power out of range. Replace the indicated I/O module(s).

83

An EMU (Environmental Monitoring Unit) has become unavailable.

n

This EMU Unit (and associated cabinet) may have been removed from the
subsystem; no action is required.

n

The cabinet has lost power; restore power to the cabinet.

n

The EM- to-EMU communications bus cable has been disconnected or broken;
replace or reconnect the cable to reestablish communications.

n

The specified EMU is broken; replace the EMU module.

n

The EMU in cabinet 0 is broken; replace the EMU module.