10. Press return and wait for FRUTIL to quiesce the device ports. This may

take several minutes. FRUTIL displays the following:

All device ports quiesced.

Using the power switch, power down expansion cabinet #2 [or

#3] and replace the PVA.

11. Power down the appropriate expansion cabinet.

12. Remove the old PVA and install the new PVA.

13. Power on the appropriate expansion cabinet. FRUTIL displays the

following:

Press return to resume device port activity.

14. Press return to resume device port activity. This may take several

minutes. When all port activity has restarted, FRUTIL displays the
following:

PVA replacement complete.

In a dual-redundant configuration, FRUTIL also displays:

The configuration has two controllers.

To restart the other controller:

1. Type ’restart other_controller’.

2. Press and hold the reset button while inserting the

program card on the slot B controller, then release the

reset button.

The controller will restart.

Field Replacement Utility terminated.

15. To allow the “other controller” to restart, type the following command:

RESTART OTHER _CONTROLLER

16. Hold the reset button while inserting the program card into the new

controller. Release the reset button and replace the ESD cover. The
controller will restart.

17. Enable failover and re-establish the dual-redundant configuration with

the following command:

SET FAILOVER COPY=THIS_CONTROLLER

This command copies the subsystem’s configuration from “this
controller” to the “other controller.”

18. Disconnect the PC or terminal from the controller’s maintenance port.