beautypg.com

Changing switches for a storageset or device, Changing switches for a storageset or device –66, Example – HP Array Controller HSG V8.7 Software User Manual

Page 144: Displaying the current switches, Changing raidset and mirrorset switches

background image

3–66

HSG80 User’s Guide

Example

The following example shows the commands you would use to delete
Stripe1, a three-member stripeset that is comprised of DISK10000,
DISK20000, and DISK30000.

SHOW STORAGESETS

DELETE D100

DELETE STRIPE1

SHOW STORAGESETS

Changing Switches for a Storageset or Device

You can optimize a storageset or device at any time by changing the
switches that are associated with it. See “Choosing Switches for
Storagesets and Devices,” page 3–39
, for an explanation of the
switches. Remember to update the storageset’s profile when you change
its switches.

Displaying the Current Switches

To display the current switches for a storageset or single-disk unit, enter
the following command at a CLI prompt:

SHOW

storageset-name or device-name

FULL

Changing RAIDset and Mirrorset Switches

Use the SET storageset-name command to change the RAIDset and
Mirrorset switches associated with an existing storageset. For example,
the following command changes the replacement policy for RAIDset
Raid1 to BEST_FIT:

SET RAID1 POLICY=BEST_FIT

Name Storageset

Uses

Used

by

STRIPE1

stripeset

DISK10000

D100

DISK20000

DISK30000