Changing switches for a storageset or device, Changing switches for a storageset or device –66, Example – HP Array Controller HSG V8.7 Software User Manual
Page 144: Displaying the current switches, Changing raidset and mirrorset switches

3–66
HSG80 User’s Guide
Example
The following example shows the commands you would use to delete
Stripe1, a three-member stripeset that is comprised of DISK10000,
DISK20000, and DISK30000.
SHOW STORAGESETS
DELETE D100
DELETE STRIPE1
SHOW STORAGESETS
Changing Switches for a Storageset or Device
You can optimize a storageset or device at any time by changing the
switches that are associated with it. See “Choosing Switches for
Storagesets and Devices,” page 3–39, for an explanation of the
switches. Remember to update the storageset’s profile when you change
its switches.
Displaying the Current Switches
To display the current switches for a storageset or single-disk unit, enter
the following command at a CLI prompt:
SHOW
storageset-name or device-name
FULL
Changing RAIDset and Mirrorset Switches
Use the SET storageset-name command to change the RAIDset and
Mirrorset switches associated with an existing storageset. For example,
the following command changes the replacement policy for RAIDset
Raid1 to BEST_FIT:
SET RAID1 POLICY=BEST_FIT
Name Storageset
Uses
Used
by
STRIPE1
stripeset
DISK10000
D100
DISK20000
DISK30000