Event Reporting: Templates and Codes
D–41
011C0011
Controller execution terminated via display of solid fault code in OCP LEDs. Note
that upon receipt of this Last Failure in a last gasp message the other controller in a
dual controller configuration will inhibit assertion of the KILL line.
n
Last Failure Parameter [0] contains the OCP LED solid fault code value.
018000A0
A powerfail interrupt occurred.
018600A0
A processor interrupt was generated with an indication that the other controller in a
dual controller configuration asserted the KILL line to disable this controller.
018700A0
A processor interrupt was generated with an indication that the (//) RESET button on
the controller module was depressed.
018800A0
A processor interrupt was generated with an indication that the program card was
removed.
018900A0
A processor interrupt was generated with an indication that the controller inactivity
watch dog timer expired.
018E2582
A NMI interrupt was generated with an indication that a memory system problem
occurred.
n
Last Failure Parameter [0] contains the memory controller register address which
encountered the error.
n
Last Failure Parameter [1] contains the memory controller’s Command Status
Register value.
018F2087
A NMI interrupt was generated with an indication that a controller system problem
occurred.
n
Last Failure Parameter [0] contains the value of read diagnostic register 0.
n
Last Failure Parameter [1] contains the value of read diagnostic register 1.
n
Last Failure Parameter [2] contains PCI status. Bits 31::24 hold PCFX PSCR
status and bits 15::08 hold PLX PSCR status.
n
Last Failure Parameter [3] contains the PCFX PDAL control/status register.
n
Last Failure Parameter [4] contains the IBUS address of error register.
n
Last Failure Parameter [5] contains the previous PDAL address of error register.
n
Last Failure Parameter [6] contains the current PDAL address of error register.
01902080
The PCI bus on the controller will not allow a master to initiate a transfer. Unable to
provide further diagnosis of the problem.
Table D–3
Last Failure Codes (Continued)
Code
Description