Upgrading the Subsystem

6–19

Note If the controller you’re installing was previously used in another
subsystem, it will need to be purged of the controller’s old
configuration (see “CONFIGURATION RESET,” page B–45).

12. Wait for FRUTIL to terminate and connect the hub cables to the new

controller.

Note One or two hub cables may be attached, depending on the
configuration.

13. To allow the “other controller”to restart, type the following command:

RESTART OTHER _CONTROLLER

14. Hold the reset button while inserting the program card into the

controller. Release the reset button and replace the ESD cover. The
controller will restart.

15. See “Configuring an HSG80 Array Controller,” page 2–3, to configure

the controller.

16. Enable failover, and re-establish the dual-redundant controller

configuration with the following command:

SET FAILOVER COPY=THIS_CONTROLLER

This command copies the subsystem’s configuration from “this
controller” to the “other controller.”

17. Disconnect the PC or terminal from the controller’s maintenance port.