HP Array Controller HSG V8.7 Software User Manual

Page 214

background image

5–18

HSG80 User’s Guide

Installing a Controller in a Dual-Redundant Controller
Configuration

Use the following steps to install a controller:

1. Connect a PC or terminal to the operational controller’s maintenance

port. The controller to which you’re connected is “this controller”; the
controller that you’re installing is the “other controller.”

2. Start FRUTIL with the following command:

RUN FRUTIL

FRUTIL displays the following:

Do you intend to replace this controller’s cache battery? Y/N

3. Enter N(o). FRUTIL displays the FRUTIL Main menu:

FRUTIL Main Menu:

1. Replace or remove a controller or cache module

2. Install a controller or cache module

3. Replace a PVA module

4. Replace an I/O module

5. Exit

Enter choice: 1, 2, 3, 4, or 5 ->

4. Enter option 2, Install a controller or cache module, from the FRUTIL

Main menu. FRUTIL displays the Install Options menu:

Install Options:

1. Other controller and cache module

2. Other controller module

3. Other cache module

4. Exit

Enter choice: 1, 2, 3, or 4 ->

5. Enter option 2, Other controller module, from the Install Options menu.

FRUTIL display the following:

Insert the slot A [or B] controller? Y/N