beautypg.com

HP Array Controller HSG V8.7 Software User Manual

Page 74

background image

2–20

HSG80 User’s Guide

Table 2–4 Key to Figure 2–7 Cabling for Dual-Redundant

Configuration with Two Hubs (optical)

1. Stop all I/O from the host to its devices on the bus to which you are

connecting the controllers.

2. Connect the Fibre Channel cable from Port 1 on controller A to Port 9

on hub 1. Repeat this step to connect the second cable from Port 1 on
controller B to Port 8 on hub 1.

3. Connect another Fibre Channel cable from Port 2 on controller A to Port

1 on hub 2. Repeat this step to connect the final cable from Port 2 on
controller B to Port 2 on hub 2.

4. Connect each hub to their respective host according to the instructions

in the Getting Started manual.

5. Route and tie the cables as desired.

6. Restart the I/O from the host. Some operating systems may require you

to restart the host to see the devices attached to the new controller.

Item Description

Part

No.

1

Dual Controller

2

12-Port Fibre Channel HUB

DHGGA-CA

3

.5 M Fibre Channel Optic cable

1 M Fibre Channel Optic cable
2 M Fibre Channel Optic cable
3 M Fibre Channel Optic cable
5 M Fibre Channel Optic cable

10 M Fibre Channel Optic cable
20 M Fibre Channel Optic cable
30 M Fibre Channel Optic cable
50 M Fibre Channel Optic cable

100 M Fibre Channel Optic cable
200 M Fibre Channel Optic cable
400 M Fibre Channel Optic cable

17–04820–01
17–04820–02
17–04820–03
17–04820–04
17–04820–05
17–04820–06
17–04820–07
17–04820–08
17–04820–09
17–04820–10
17–04820–11