2–20
HSG80 User’s Guide
Table 2–4 Key to Figure 2–7 Cabling for Dual-Redundant
Configuration with Two Hubs (optical)
1. Stop all I/O from the host to its devices on the bus to which you are
connecting the controllers.
2. Connect the Fibre Channel cable from Port 1 on controller A to Port 9
on hub 1. Repeat this step to connect the second cable from Port 1 on
controller B to Port 8 on hub 1.
3. Connect another Fibre Channel cable from Port 2 on controller A to Port
1 on hub 2. Repeat this step to connect the final cable from Port 2 on
controller B to Port 2 on hub 2.
4. Connect each hub to their respective host according to the instructions
in the Getting Started manual.
5. Route and tie the cables as desired.
6. Restart the I/O from the host. Some operating systems may require you
to restart the host to see the devices attached to the new controller.
Item Description
Part
No.
1
Dual Controller
—
2
12-Port Fibre Channel HUB
DHGGA-CA
3
.5 M Fibre Channel Optic cable
1 M Fibre Channel Optic cable
2 M Fibre Channel Optic cable
3 M Fibre Channel Optic cable
5 M Fibre Channel Optic cable
10 M Fibre Channel Optic cable
20 M Fibre Channel Optic cable
30 M Fibre Channel Optic cable
50 M Fibre Channel Optic cable
100 M Fibre Channel Optic cable
200 M Fibre Channel Optic cable
400 M Fibre Channel Optic cable
17–04820–01
17–04820–02
17–04820–03
17–04820–04
17–04820–05
17–04820–06
17–04820–07
17–04820–08
17–04820–09
17–04820–10
17–04820–11
17–04820–12