Event Reporting: Templates and Codes

D–31

03DE450A

During device initialization, the device reported the SCSI Sense Key
ABORTED COMMAND. This indicates the target aborted the
command. The initiator may be able to recover by trying the command
again.

41

03DF450A

During device initialization, the device reported the SCSI Sense Key
EQUAL. This indicates a SEARCH DATA command has satisfied an
equal comparison.

41

03E0450A

During device initialization, the device reported the SCSI Sense Key
VOLUME OVERFLOW. This indicates a buffered peripheral device has
reached the end-of-partition and data may remain in the buffer that has
not been written to the medium. A RECOVER BUFFERED DATA
command(s) may be issued to read the unwritten data from the buffer.

41

03E1450A

During device initialization, the device reported the SCSI Sense Key
MISCOMPARE. This indicates the source data did not match the data
read from the medium.

41

03E2450A

During device initialization, the device reported a reserved SCSI Sense
Key.

41

03E40F64

The EMU has indicated that Termination Power is good on all ports.
Note that in this instance the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.

41

03E58002

The EMU has detected bad Termination Power on the indicated port.
Note that in this instance the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.

41

03EE0064

The EMU for the cabinet indicated by the Associated Port field has
become available. Note that the Associated Target, Associated
Additional Sense Code, and the Associated Additional Sense Code
Qualifier fields are undefined.

41

03EF8301

The EMU for the cabinet indicated by the Associated Port field has
become unavailable. Note that the Associated Target, Associated
Additional Sense Code, and the Associated Additional Sense Code
Qualifier fields are undefined.

41

03F10502

The SWAP interrupt from the device port indicated by the Associated
Port field can not be cleared. All SWAP interrupts from all ports will be
disabled until corrective action is taken. When SWAP interrupts are
disabled, both controller front panel button presses and removal/
insertion of devices are not detected by the controller. Note that in this
instance the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.

41

Table D–1

Instance Codes (Continued)

Instance

Code

Description

Template