HP Array Controller HSG V8.7 Software User Manual
Page 457
Event Reporting: Templates and Codes
D–23
02613801
Memory diagnostics performed during controller initialization detected
that the DIMM in location 1 failed on the cache module. Note that in this
instance the Byte Count field in undefined.
14
02623801
Memory diagnostics performed during controller initialization detected
that the DIMM in location 2 failed on the cache module. Note that in this
instance the Byte Count field in undefined.
14
02633801
Memory diagnostics performed during controller initialization detected
that the DIMM in location 3 failed on the cache module. Note that in this
instance the Byte Count field in undefined.
14
02643801
Memory diagnostics performed during controller initialization detected
that the DIMM in location 4 failed on the cache module. Note that in this
instance the Byte Count field in undefined.
14
02653C01
Memory diagnostics performed during controller initialization detected
that the DIMM in location 3 on the other controller’s cache module (on
mirrored cache) failed. Mirroring has been disabled. Note that in this
instance the Byte Count field is undefined.
14
02663C01
Memory diagnostics performed during controller initialization detected
that the DIMM in location 4 on the other controller’s cache module (on
mirrored cache) failed. Mirroring has been disabled. Note that in this
instance the Byte Count field is undefined.
14
02675201
The device specified in the Device Locator field has been removed from
the RAIDset associated with the logical unit. The removed device is now
in the Failedset. The RAIDset is now in Reduced state.
51
0268530A
The device specified in the Device Locator field failed to be added to the
RAIDset associated with the logical unit. The device will remain in the
Spareset.
51
02695401
The device specified in the Device Locator field failed to be added to the
RAIDset associated with the logical unit. The failed device has been
moved to the Failedset.
51
026A5001
The RAIDset associated with the logical unit has gone inoperative.
51
026B0064
The RAIDset associated with the logical unit has transitioned from
Normal state to Reconstructing state.
51
026C0064
The RAIDset associated with the logical unit has transitioned from
Reconstructing state to Normal state.
51
026D5201
The device specified in the Device Locator field has been removed from
the Mirrorset associated with the logical unit. The removed device is
now in the Failedset.
51
Table D–1
Instance Codes (Continued)
Instance
Code
Description
Template