beautypg.com

HP Array Controller HSG V8.7 Software User Manual

Page 428

background image

C–4

HSG80 User’s Guide

■● ● ● ❍ ❍ ❍

38

Controller operation terminated

Last Failure event required
termination of controller operation
(e.g. SHUT DOWN VIA CLI)

Reset controller

■● ● ❍ ● ● ●

37

Software-induced controller reset
expected

Software-induced reset failed

Replace controller

■● ● ❍ ● ● ❍

36

Hardware-induced controller reset
expected

Automatic hardware reset failed

Replace controller

■● ● ❍ ● ❍ ●

35

An unexpected bugcheck occurred
during Last Failure processing

Last Failure Processing interrupted
by another Last Failure event

Reset controller

■● ● ❍ ❍ ●●

33

NVPM structure revision too low

NVPM structure revision number
is less than the one that can be
handled by the software version
attempting to be executed

Verify that the program card contains
the latest software version. If the error
persists, replace controller.

■● ● ❍ ❍ ●❍

32

Code load program card write
failure

Attempt to update program card
failed

Replace card

■● ● ❍ ❍ ❍ ●

31

ILF$INIT unable to allocate
memory

Attempt to allocate memory by
ILF$INIT failed

Replace controller

Table C–1

Solid OCP Patterns (Continued)

Pattern

OCP

Code

Error

Repair Action