Event Reporting: Templates and Codes
D–47
029A0100
Invalid cache buffer metadata detected while scanning the Buffer Metadata Array.
Found a page containing dirty data but the corresponding Device Correlation Array
entry does exist.
029D0100
Invalid metadata combination detected in build_bad_raid_node.
029F0100
The Cache Manager software has insufficient resources to handle a buffer request
pending.
02A00100
VA change state is trying to change device affinity and the cache has data for this
device.
02A10100
Pubs not one when transportable
02A20100
Pubs not one when transportable
02A30100
No available data buffers. If the cache module exists then this is true after testing the
whole cache. Otherwise there were no buffers allocated from BUFFER memory on the
controller module.
02A40100
A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory when
allocating VAXDs.
02A50100
A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory when
allocating DILPs.
02A60100
A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory when
allocating Change State Work Items.
02A70100
A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory when
allocating VA Request Items.
02A90100
Too many pending FOC$SEND requests by the Cache Manager. Code is not designed
to handle more than one FOC$SEND to be pending because there’s no reason to
expect more than one pending.
02AA0100
An invalid call was made to CACHE$DEALLOCATE_CLD. Either that device had
dirty data or it was bound to a RAIDset.
02AB0100
An invalid call was made to CACHE$DEALLOCATE_SLD. A RAIDset member
either had dirty data or write-back already turned on.
02AC0100
An invalid call was made to CACHE$DEALLOCATE_SLD. The RAIDset still has
data (strip nodes).
Table D–3
Last Failure Codes (Continued)
Code
Description