5–16

HSG80 User’s Guide

5. Enter N(o). FRUTIL displays the FRUTIL Main menu:

FRUTIL Main Menu:

1. Replace or remove a controller or cache module

2. Install a controller or cache module

3. Replace a PVA module

4. Replace an I/O module

5. Exit

Enter choice: 1, 2, 3, 4, or 5 ->

6. Enter option 1, Replace or remove a controller or cache module, from

the FRUTIL Main menu. FRUTIL displays the Replace or Remove
Options menu:

Replace or remove Options:

1. Other controller and cache module

2. Other controller module

3. Other cache module

4. Exit

Enter choice: 1, 2, 3, or 4 ->

7. Enter option 2, Other controller module, from the Replace or Remove

Options menu. FRUTIL displays the following:

Slot Designations

(front view)

[ --- EMU --- ][ --- PVA --- ]

[ -------- Controller A ------- ]

[ -------- Controller B ------- ]

[ Cache Module A ][ Cache Module B ]

Remove the slot A [or B] controller? Y/N

8. Type Y(es) and press return. FRUTIL displays the following:

Quiescing all device ports. Please wait...

Device Port 1 quiesced.

Device Port 2 quiesced.

Device Port 3 quiesced.

Device Port 4 quiesced.

Device Port 5 quiesced.

Device Port 6 quiesced.

All device ports quiesced.

Remove the slot A [or B] controller (the one without a

blinking green LED) within 2 minutes.