HP Array Controller HSG V8.7 Software User Manual
Page 212
5–16
HSG80 User’s Guide
5. Enter N(o). FRUTIL displays the FRUTIL Main menu:
FRUTIL Main Menu:
1. Replace or remove a controller or cache module
2. Install a controller or cache module
3. Replace a PVA module
4. Replace an I/O module
5. Exit
Enter choice: 1, 2, 3, 4, or 5 ->
6. Enter option 1, Replace or remove a controller or cache module, from
the FRUTIL Main menu. FRUTIL displays the Replace or Remove
Options menu:
Replace or remove Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
Enter choice: 1, 2, 3, or 4 ->
7. Enter option 2, Other controller module, from the Replace or Remove
Options menu. FRUTIL displays the following:
Slot Designations
(front view)
[ --- EMU --- ][ --- PVA --- ]
[ -------- Controller A ------- ]
[ -------- Controller B ------- ]
[ Cache Module A ][ Cache Module B ]
Remove the slot A [or B] controller? Y/N
8. Type Y(es) and press return. FRUTIL displays the following:
Quiescing all device ports. Please wait...
Device Port 1 quiesced.
Device Port 2 quiesced.
Device Port 3 quiesced.
Device Port 4 quiesced.
Device Port 5 quiesced.
Device Port 6 quiesced.
All device ports quiesced.
Remove the slot A [or B] controller (the one without a
blinking green LED) within 2 minutes.