HP Array Controller HSG V8.7 Software User Manual

Page 431

background image

LED Codes

C–7

■● ❍ ❍ ● ❍ ●

25

Recursive Bugcheck detected

The same bugcheck has occurred
three times within ten minutes, and
controller operation has
terminated.

Reset the controller. If this fault pattern
is displayed repeatedly, follow the
repair action(s) associated with the Last
Failure code that is repeatedly
terminating controller execution.

■❍ ❍ ❍ ❍ ❍ ❍

0

No program card detected or kill
asserted by other controller

Controller unable to read program
card

Ensure that program card is properly
seated while resetting the controller. If
the error persists, try the card with
another controller; or replace the card.
Otherwise, replace the controller that
reported the error.

❏❍ ❍ ❍ ❍ ❍ ❍

0

Catastrophic controller or power
failure

Check power. If good, reset controller.
If problem persists, reseat controller
module and reset controller. If problem
is still evident, replace controller
module.

Table C–1

Solid OCP Patterns (Continued)

Pattern

OCP

Code

Error

Repair Action