Table 4–2 event-code types, Event-code types –19 – HP Array Controller HSG V8.7 Software User Manual
Page 173
Troubleshooting
4–19
3. Show one or more of the entries with the following command:
DESCRIBE
code_type code#
where code_type is one of those listed in Table 4–2 and code# is the
alpha-numeric value displayed in the entry. The code types marked with
an asterisk (*) require multiple code numbers.
Example
The following example shows the FMU translation of a last-failure
code.
FMU>DESCRIBE LAST_FAILURE_CODE 206C0020
Last Failure Code: 206C0020
Description: Controller was forced to restart in order for new con-
troller code image to take effect.
Reporting Component: 32.(20)
Description: Command Line Interpreter
Reporting component’s event number: 108.(6C)
Restart Type: 2.(02)
Description: Automatic hardware restart
Instance Codes and Last-Failure Codes
Instance codes identify and accompany significant events that do not
cause the controller to terminate operation; last-failure codes identify
and accompany failure events that cause the controller to stop
operating. Last-failure codes are sent to the host only after the affected
controller is restarted successfully.
Table 4–2
Event-Code Types
Event-Code Type
ASC_ASCQ_CODE*
COMPONENT_CODE
CONTROLLER_UNIQUE_ASC_ASCQ_CODE*
DEVICE_TYPE_CODE
EVENT _THRESHOLD_CODE
INSTANCE_CODE
LAST_FAILURE_CODE
REPAIR_ACTION_CODE
RESTART_TYPE
SCSI_COMMAND_OPERATION_CODE*
SENSE_DATA_QUALIFIERS*
SENSE_KEY_CODE
TEMPLATE_CODE