HP Array Controller HSG V8.7 Software User Manual
Page 474
D–40
HSG80 User’s Guide
01160108
The I960 reported a machine fault (parity error).
n
Last Failure Parameter [0] contains the RESERVED value.
n
Last Failure Parameter [1] contains the access type value.
n
Last Failure Parameter [2] contains the access address value.
n
Last Failure Parameter [3] contains the number of faults value.
n
Last Failure Parameter [4] contains the PC value.
n
Last Failure Parameter [5] contains the AC value.
n
Last Failure Parameter [6] contains the fault type and subtype values.
n
Last Failure Parameter [7] contains the RIP value.
01170108
The I960 reported a machine fault (parity error) while an NMI was being processed.
n
Last Failure Parameter [0] contains the RESERVED value.
n
Last Failure Parameter [1] contains the access type value.
n
Last Failure Parameter [2] contains the access address value.
n
Last Failure Parameter [3] contains the number of faults value.
n
Last Failure Parameter [4] contains the PC value.
n
Last Failure Parameter [5] contains the AC value.
n
Last Failure Parameter [6] contains the fault type and subtype values.
n
Last Failure Parameter [7] contains the RIP value.
01180105
A machine fault (parity error) occurred during EXEC$BUGCHECK processing.
n
Last Failure Parameter [0] contains the executive flags value.
n
Last Failure Parameter [1] contains the RIP from the machine fault stack.
n
Last Failure Parameter [2] contains the read diagnostic register 0 value.
n
Last Failure Parameter [3] contains the FX Chip CSR value.
n
Last Failure Parameter [4] contains the SIP last failure code value.
011B0108
The I960 reported a machine fault (nonparity error).
n
Last Failure Parameter [0] contains the Fault Data (2) value.
n
Last Failure Parameter [1] contains the Fault Data (1) value.
n
Last Failure Parameter [2] contains the Fault Data (0) value.
n
Last Failure Parameter [3] contains the Number of Faults value.
n
Last Failure Parameter [4] contains the PC value.
n
Last Failure Parameter [5] contains the AC value.
n
Last Failure Parameter [6] contains the Fault Flags, Type and Subtype values.
n
Last Failure Parameter [7] contains the RIP value (actual).
Table D–3
Last Failure Codes (Continued)
Code
Description