HP Array Controller HSG V8.7 Software User Manual
Page 447
Event Reporting: Templates and Codes
D–13
Device Services Non-Transfer Error Event Sense Data Response
The HSG80 controller Device Services software component reports
errors detected while performing non-transfer work related to disk
(including CD-ROM and optical memory) device operations via the
Device Services Non-Transfer Event Sense Data Response (see Figure
D–9).
n
Instance Codes (byte offset 32-35) are described in Table D–1,
“Instance Codes” on page D–18.
n
ASC and ASCQ codes (byte offsets 12 and 13) are described in
Table D–7, “ASC and ASCQ Codes” on page D–85.
Figure D–9
Template 41 - Device Services Non-Transfer Error
Event Sense Data Response Format
off
bit
7
6
5
4
3
2
1
Unusd
Unused
Unused
Unused
Unused
Unused
Unused
Error Code
0
1
2
3-6
7
8-11
12
13
14
15–17
18–31
32-35
36
37
38–53
54–69
70-73
74-75
76
77–103
104
105
106
107
108–159
0
Sense Key
Additional Sense Length
Additional Sense Code (ASC)
Additional Sense Code Qualifier (ASCQ)
Reserved
Reserved
Reserved
Reserved
Instance Code
Template
Template Flags
Controller Board Serial Number
Controller Software Revision Level
Associated Port
Associated Target
Associated Additional Sense Code
Associated Additional Sense Code Qualifier
Reserved
LUN Status
CXO6182A
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (85 pages)
- Software de HP StoreVirtual VSA (127 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)