Table d–2 controller restart codes – HP Array Controller HSG V8.7 Software User Manual
Page 471
Event Reporting: Templates and Codes
D–37
HW
This hardware/software flag is located at byte offset 104, bit 7. If this
flag is equal to 1, the unrecoverable condition is due to a hardware-
detected fault. If this flag is equal to 0, the unrecoverable condition is
due to an inconsistency with the software, or an intentional restart or
shutdown of the controller was requested.
Restart Code
Located at byte offset 104, bits 4-6, the Restart Code describes the
actions taken to restart the controller after the unrecoverable condition
was detected. Table D–2 gives a description of restart codes and their
descriptions.
Parameter Count
The Parameter Count, located at byte offset 104, bits 0-3, indicates the
number of Last Failure Parameters containing supplemental
information supplied.
Repair Action
The Repair Action found at byte offset 105 indicates the recommended
repair action code assigned to the event. This value is used during
Symptom-Directed Diagnosis procedures to determine what
notification/recovery action should be taken. For more details, see
“Recommended Repair Action Codes,” page D–77.
Error Numbers
Located at byte offset 106, the Error Number, when combined with the
value contained in the Component ID field, uniquely-identifies the
condition detected.
Table D–2
Controller Restart Codes
Restart Code
Description
0
Full software restart
1
No restart
2
Automatic hardware restart