HP Array Controller HSG V8.7 Software User Manual

Page 206

background image

5–10

HSG80 User’s Guide

7. Enter option 1, Other controller and cache module, from the Replace or

Remove Options menu. FRUTIL displays the following:

Slot Designations

(front view)

[ --- EMU --- ][ --- PVA --- ]

[ -------- Controller A ------- ]

[ -------- Controller B ------- ]

[ Cache Module A ][ Cache Module B ]

Remove both the slot A [or B] controller and cache module? Y/N

8. Enter Y(es) and press return. FRUTIL displays the following:

Quiescing all device ports. Please wait...

Device Port 1 quiesced.

Device Port 2 quiesced.

Device Port 3 quiesced.

Device Port 4 quiesced.

Device Port 5 quiesced.

Device Port 6 quiesced.

All device ports quiesced.

Remove the slot A [or B] controller (the one without a

blinking green LED) within 4 minutes.

Caution The device ports must quiesce before removing the controller.
Failure to allow the ports to quiesce may result in data loss. Quiescing
may take several minutes.

ESD can easily damage a controller or a cache module. Wear a snug-
fitting, grounded ESD wrist strap.

Note A countdown timer allows a total of four minutes to remove the
controller and cache module. If you exceed four minutes, “this
controller” will exit FRUTIL and resume operations.

9. Remove the Hub cables from the “other controller.”

Note One or two hub cables may be attached, depending on the
configuration.