Configuring a striped mirrorset, Configuring a striped mirrorset –59 – HP Array Controller HSG V8.7 Software User Manual
Page 137

Creating Storagesets
3–59
Configuring a Striped Mirrorset
See Chapter 3, “Creating Storagesets,” for information about creating a
profile and understanding the switches you can set for this kind of
storage unit.
To configure a striped mirrorset:
1. Create—but do not initialize—at least two mirrorsets.
2. Create a stripeset and specify the mirrorsets it contains. Use the
following command:
ADD STRIPESET
mirrorset_1 mirrorset_2
3. Initialize the stripeset. If you want to set any Initialize switches, you
must do so in this step. Use the following command:
INITIALIZE
stripeset-name switch
See page B–121 of Appendix B for a complete list of valid mirrorset
switches and values.
4. Present the stripeset to the host by giving it a unit number the host can
recognize. Optionally, you can append Unit switch values. If you do not
specify switch values, the default values are applied.
Use the following command to present the stripeset to the host:
ADD UNIT
unit-number stripeset-name switch
5. Verify the striped mirrorset configuration and switches. Use the
following command:
SHOW
stripeset-name
6. Verify the unit configuration and switches. Use the following command:
SHOW
unit-number