Step 9, Step 10 – HP Array Controller HSG V8.7 Software User Manual
Page 58
2–4
HSG80 User’s Guide
If this is a single configuration with a single hub, set PORT 2 off-line.
If this is a dual-redundant configuration, the “other controller” inherits
“this controller’s” port topology.
See Appendix B, “CLI Commands,” for more information about using
the SET THIS_CONTROLLER PORT_n_TOPOLOGY= command.
8. If you selected LOOP_HARD for the port topology, specify the
arbitrated loop physical address (ALPA) for the host ports.
SET THIS_CONTROLLER PORT_1_ALPA=
“address”
SET THIS_CONTROLLER PORT_2_ALPA=“
address”
If this is a dual-redundant configuration, the “other controller” inherits
“this controller’s” port ALPA addresses.
See Appendix B, “CLI Commands,” for more information about using
the SET OTHER_CONTROLLER PORT_n_ALPA= command.
9. Put “this controller” into transparent failover mode. Use the following
syntax:
SET FAILOVER COPY = THIS_CONTROLLER
The “other controller” inherits “this controller’s” configuration, then
restarts. Wait for it to return to normal operation before continuing.
See details about failover modes in “Selecting a Failover Mode,” page
2–10.
10. Put “this controller” in multiple-bus failover mode using the follwing
syntax:
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
The “other controller” inherits “this controller’s” configuration, then
restarts. Wait for it to return to normal operation before continuing.
See “Selecting a Failover Mode,” page 2–10, for details about failover
modes.
11. Optional: Change the CLI prompt. Type the following command:
SET THIS_CONTROLLER PROMPT =
“new prompt”