Step 9, Step 10 – HP Array Controller HSG V8.7 Software User Manual

Page 58

background image

2–4

HSG80 User’s Guide

If this is a single configuration with a single hub, set PORT 2 off-line.

If this is a dual-redundant configuration, the “other controller” inherits
“this controller’s” port topology.

See Appendix B, “CLI Commands,” for more information about using
the SET THIS_CONTROLLER PORT_n_TOPOLOGY= command.

8. If you selected LOOP_HARD for the port topology, specify the

arbitrated loop physical address (ALPA) for the host ports.

SET THIS_CONTROLLER PORT_1_ALPA=

“address”

SET THIS_CONTROLLER PORT_2_ALPA=

address”

If this is a dual-redundant configuration, the “other controller” inherits
“this controller’s” port ALPA addresses.

See Appendix B, “CLI Commands,” for more information about using
the SET OTHER_CONTROLLER PORT_n_ALPA= command.

9. Put “this controller” into transparent failover mode. Use the following

syntax:

SET FAILOVER COPY = THIS_CONTROLLER

The “other controller” inherits “this controller’s” configuration, then
restarts. Wait for it to return to normal operation before continuing.

See details about failover modes in “Selecting a Failover Mode,” page
2–10.

10. Put “this controller” in multiple-bus failover mode using the follwing

syntax:

SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER

The “other controller” inherits “this controller’s” configuration, then
restarts. Wait for it to return to normal operation before continuing.

See “Selecting a Failover Mode,” page 2–10, for details about failover
modes.

11. Optional: Change the CLI prompt. Type the following command:

SET THIS_CONTROLLER PROMPT =

“new prompt”