Event Reporting: Templates and Codes

D–57

03390108

An unknown interrupt code was found in a device port’s DSPS register.

n

Last Failure Parameter [0] contains the PCB port_ptr value.

n

Last Failure Parameter [1] contains the PCB copy of the device port TEMP
register.

n

Last Failure Parameter [2] contains the PCB copy of the device port DBC register.

n

Last Failure Parameter [3] contains the PCB copy of the device port DNAD
register.

n

Last Failure Parameter [4] contains the PCB copy of the device port DSP register.

n

Last Failure Parameter [5] contains the PCB copy of the device port DSPS
register.

n

Last Failure Parameter [6] contains the PCB copies of the device port SSTAT2/
SSTAT1/SSTAT0/DSTAT registers.

n

Last Failure Parameter [7] contains the PCB copies of the device port LCRC/
RESERVED/ISTAT/DFIFO registers.

033C0101

An invalid code was seen by the error recovery thread in the er_funct_step field of the
PCB.

n

Last Failure Parameter [0] contains the PCB er_funct_step code.

033E0108

An attempt was made to restart a device port at the SDP DBD.

n

Last Failure Parameter [0] contains the PCB port_ptr value.

n

Last Failure Parameter [1] contains the PCB copy of the device port TEMP
register.

n

Last Failure Parameter [2] contains the PCB copy of the device port DBC register.

n

Last Failure Parameter [3] contains the PCB copy of the device port DNAD
register.

n

Last Failure Parameter [4] contains the PCB copy of the device port DSP register.

n

Last Failure Parameter [5] contains the PCB copy of the device port DSPS
register.

n

Last Failure Parameter [6] contains the PCB copies of the device port SSTAT2/
SSTAT1/SSTAT0/DSTAT registers.

n

Last Failure Parameter [7] contains the PCB copies of the device port LCRC/
RESERVED/ISTAT/DFIFO registers.

Table D–3

Last Failure Codes (Continued)

Code

Description