HP Array Controller HSG V8.7 Software User Manual
Page 508

D–74
HSG80 User’s Guide
447F0100
The Host Port Transport memory for LOGI parameters.
44800101
An illegal status was returned to the name service command error handler.
n
Last Failure Parameter [0] contains error value.
44810101
An illegal status was returned to the PLOGI command error handler.
n
Last Failure Parameter [0] contains error value.
44820101
An illegal abort type was given to the Host Port Transport abort handler.
n
Last Failure Parameter [0] contains abort type.
44830101
An illegal failover request was given to the Host Port Transport request handler.
n
Last Failure Parameter [0] contains failover request.
44840101
An illegal failover response was given to the Host Port Transport failover response
handler.
n
Last Failure Parameter [0] contains failover response.
44850100
The Host Port Transport failover control had a bad send count.
44860100
Unable to allocate enough ESD structures for Fibre Channel Host Port Transport
software layer.
44870101
An illegal abort type was given to the Host Port Transport abort handler.
n
Last Failure Parameter [0] contains abort type.
44892091
Host Port Hardware diagnostic field at system initialization.
n
Last Failure Parameter [0] contains failed port number.
64000100
Insufficient buffer memory to allocate data structures needed to propagate SCSI Mode
Select changes to other controller.
64010100
During an initialization of LUN specific mode pages, an unexpected device type was
encountered.
64020100
A DD is already in use by a RCV DIAG command - cannot get two RCV_DIAGs
without sending the data for the first.
80010100
An HTB was not available to issue an I/O when it should have been.
80030100
DILX tried to release a facility that wasn’t reserved by DILX.
80040100
DILX tried to change the unit state from MAINTENANCE_MODE to NORMAL but
was rejected because of insufficient resources.
Table D–3
Last Failure Codes (Continued)
Code
Description