D–42

HSG80 User’s Guide

01910084

A Cache Module was inserted or removed.

n

Last Failure Parameter [0] contains the value of actual Cache Module A exists
state.

n

Last Failure Parameter [1] contains the value of actual Cache Module B exists
state.

n

Last Failure Parameter [2] contains the value of expected Cache Module A exists
state.

n

Last Failure Parameter [3] contains the value of expected Cache Module B exists
state.

01920186

Unable to read the FX because a Device Port or a Host Port locked the PDAL bus.

n

Last Failure Parameter [0] contains the value of read diagnostic register 0.

n

Last Failure Parameter [1] contains the value of read diagnostic register 1.

n

Last Failure Parameter [2] contains the value of read diagnostic register 2.

n

Last Failure Parameter [3] contains the value of write diagnostic register 0.

n

Last Failure Parameter [4] contains the value of write diagnostic register 1.

n

Last Failure Parameter [5] contains the IBUS address of error register.

01932588

An error has occurred on the CDAL.

n

Last Failure Parameter [0] contains the value of read diagnostic register 0.

n

Last Failure Parameter [1] contains the value of read diagnostic register 1.

n

Last Failure Parameter [2] contains the value of write diagnostic register 0.

n

Last Failure Parameter [3] contains the value of write diagnostic register 1.

n

Last Failure Parameter [4] contains the IBUS address of error register.

n

Last Failure Parameter [5] contains the PCFX CDAL control / status register.

n

Last Failure Parameter [6] contains the previous CDAL address of error register.

n

Last Failure Parameter [7] contains the current CDAL address of error register.

01942088

An error has occurred on the PDAL.

n

Last Failure Parameter [0] contains the value of read diagnostic register 0.

n

Last Failure Parameter [1] contains the value of read diagnostic register 1.

n

Last Failure Parameter [2] contains the value of write diagnostic register 0.

n

Last Failure Parameter [3] contains the value of write diagnostic register 1.

n

Last Failure Parameter [4] contains the IBUS address of error register.

n

Last Failure Parameter [5] contains the PCFX PDAL control / status register.

n

Last Failure Parameter [6] contains the previous PDAL address of error register.

n

Last Failure Parameter [7] contains the current PDAL address of error register.

Table D–3

Last Failure Codes (Continued)

Code

Description