beautypg.com

Retry_errors unwriteable_data – HP Array Controller HSG V8.7 Software User Manual

Page 365

background image

CLI Commands

B–93

RETRY_ERRORS UNWRITEABLE_DATA

Causes the controller to attempt to write previously unwriteable data
from the write-back cache to the devices. If a container fails, preventing
the data in write-back cache to be written to the container, an
unwriteable data error is reported. If possible, correct the condition that
caused the unwriteable data and try the write operation again. No data
is lost if the retry fails.

Syntax

RETRY_ERRORS unit-number UNWRITEABLE_DATA

Parameter

unit-number
Identifies the unit number to which the data contained in write-back
cache tries to write. The unit-number is the same name given to the unit
when it was created using the ADD UNIT command.

Example

This example shows how to retry writing the cached data previously
marked unwriteable to disk unit D103:

RETRY_ERRORS D103 UNWRITEABLE_DATA

See also

CLEAR_ERRORS unit-number UNWRITEABLE_DATA