Solid ocp patterns, Table c–1 solid ocp patterns (continued) – HP Array Controller HSG V8.7 Software User Manual
Page 427
LED Codes
C–3
Solid OCP Patterns
Table C–1
Solid OCP Patterns
Pattern
OCP
Code
Error
Repair Action
■● ● ● ●● ●
3F
DAEMON diagnostic failed hard
in non-fault tolerant mode
DAEMON diagnostic detected
critical hardware component
failure; controller can no longer
operate
Verify that cache module is present. If
the error persists, replace controller.
■● ● ● ●❍ ●
3D
NVPM structure revision greater
than image’s
NVPM structure revision number
is greater than the one that can be
handled by the software version
attempting to be executed
Replace program card with one that
contains the latest software version
■● ● ● ●❍ ❍
3C
NVPM write loop hang
Attempt to write data to NVPM
failed
Replace controller
■● ● ● ❍ ● ●
3B
NVPM read loop hang
Attempt to read data from NVPM
failed
Replace controller
■● ● ● ❍ ● ❍
3A
An unexpected NMI occurred
during Last Failure processing
Last Failure processing interrupted
by a Non-Maskable Interrupt
(NMI)
Reset controller
■● ● ● ❍ ❍ ●
39
NVPM configuration inconsistent
Device configuration within the
NVPM is inconsistent
Reset controller
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- XP Array Manager Software (101 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant High Availability Storage Server (72 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)