Table b–5 emu set point temperatures – HP Array Controller HSG V8.7 Software User Manual
Page 386

B–114
HSG80 User’s Guide
Table B–5 lists the valid EMU set-point temperatures in both
Fahrenheit and Celsius.
If any of the setpoints assigned to a slave EMU do not match the
corresponding setpoints assigned to the master EMU, the slave EMU
settings change to match the corresponding master EMU settings.
Refer to the enclosure documentation for detailed information about
setting the EMU temperature set points.
FANSPEED=HIGH
FANSPEED=AUTOMATIC (Default)
Sets the speed at which the fan operates.
Select FANSPEED=HIGH to force the fans in all connected cabinets to
operate at high speed continuously.
Select FANSPEED=AUTOMATIC to allow the EMU to control the fan
speed for the fans in all connected cabinets.
Table B–5 EMU Set Point Temperatures
ºC
ºF
ºC
ºF
ºC
ºF
ºC
ºF
ºC
ºF
0
32
10
50
20
68
30
86
40
104
1
34
11
52
21
70
31
88
41
106
2
46
12
54
22
72
32
90
42
108
3
37
13
55
23
73
33
91
43
109
4
39
14
57
24
75
34
93
44
111
5
41
15
59
25
77
35
95
45
113
6
43
16
61
26
79
36
97
46
115
7
45
17
63
27
81
37
99
47
117
8
46
18
64
28
82
38
100
48
118
9
48
19
66
29
84
39
102
49
120
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)